A “skid-mounted multiphase pump” (also known as an “intelligent mixed-transfer device skid unit”) mainly consists of the multiphase pump main unit, piping network, metering device, filter, safety valve, supporting valves and instruments, and part of the control system. See the diagram:
Note: The intelligent frequency converter control cabinet is generally not installed inside the skid; it can be installed indoors in the central control room.
A “single unit skid-mounted multiphase pump” refers to a skid-mounted multiphase pump where the main unit is a single unit (as shown in the figure).
Skid-mounted multiphase pumps in hybrid units refer to pumps with two or more main units. The connection between the main units can be either series or parallel. This is primarily used to address the staged transport of high-gas-content media under high pressure, resulting in greater energy efficiency, more stable and reliable operation, and easier maintenance. A series structure is shown in the diagram below (top view):
This multiphase pump is manufactured as a skid, consisting of the main multiphase pump unit (two main units connected in series), piping, metering device, filter, safety valve, matching valves and instruments, and part of the control system. The intelligent frequency converter control cabinet is located outside the skid.
Series units are suitable for conveying media with large pressure differentials. By connecting two (or more) main units in series, the gas is compressed and conveyed twice, achieving high-efficiency and energy-saving conveying.
a. Incoming oil and gas enter through the metering device inlet, are metered, and then enter the mixed-transfer pump inlet pipeline. After passing through the filter and being pressurized by the pump, they enter the oil-gas separation pipeline network from the outlet. After oil-gas separation, they are output through the pipeline network outlet.
b. A
c. A safety valve is provided at the top of the pipeline network, with a set opening pressure, controlled by the valve, and connected to the external pipeline by a flange.
d. A bypass pipeline is formed by connecting the pump inlet pipeline to the network outlet pipeline, controlled by valves, and opened during production stoppages or skid unit malfunctions.
All performance indicators of products are strictly tested, and the professional QC team controls each process.
We promise that we can unconditionally solve any quality problems with the pumps sold.
We recommend suitable products according to the actual needs of customers, and we can do OEM for you.